Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Epilepsia ; 61(8): 1749-1757, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32658325

RESUMEN

OBJECTIVE: The RNS System is a direct brain-responsive neurostimulation system that is US Food and Drug Administration-approved for adults with medically intractable focal onset seizures based on safety and effectiveness data from controlled clinical trials. The purpose of this study was to retrospectively evaluate the real-world safety and effectiveness of the RNS System. METHODS: Eight comprehensive epilepsy centers conducted a chart review of patients treated with the RNS System for at least 1 year, in accordance with the indication for use. Data included device-related serious adverse events and the median percent change in disabling seizure frequency from baseline at years 1, 2, and 3 of treatment and at the most recent follow-up. RESULTS: One hundred fifty patients met the criteria for analysis. The median reduction in seizures was 67% (interquartile range [IQR] = 33%-93%, n = 149) at 1 year, 75% (IQR = 50%-94%, n = 93) at 2 years, 82% (IQR = 50%-96%, n = 38) at ≥3 years, and 74% (IQR = 50%-96%, n = 150) at last follow-up (mean = 2.3 years). Thirty-five percent of patients had a ≥90% seizure frequency reduction, and 18% of patients reported being clinically seizure-free at last follow-up. Seizure frequency reductions were similar regardless of patient age, age at epilepsy onset, duration of epilepsy, seizure onset in mesial temporal or neocortical foci, magnetic resonance imaging findings, prior intracranial monitoring, prior epilepsy surgery, or prior vagus nerve stimulation treatment. The infection rate per procedure was 2.9% (6/150 patients); five of the six patients had an implant site infection, and one had osteomyelitis. Lead revisions were required in 2.7% (4/150), and 2.0% (3/150) of patients had a subdural hemorrhage, none of which had long-lasting neurological consequences. SIGNIFICANCE: In this real-world experience, safety was similar and clinical seizure outcomes exceeded those of the prospective clinical trials, corroborating effectiveness of this therapy and suggesting that clinical experience has informed more effective programming.


Asunto(s)
Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/terapia , Neuroestimuladores Implantables , Adolescente , Adulto , Anciano , Electrocorticografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
2.
Epilepsia ; 61(3): 408-420, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32072621

RESUMEN

OBJECTIVE: To describe seizure outcomes in patients with medically refractory epilepsy who had evidence of bilateral mesial temporal lobe (MTL) seizure onsets and underwent MTL resection based on chronic ambulatory intracranial EEG (ICEEG) data from a direct brain-responsive neurostimulator (RNS) system. METHODS: We retrospectively identified all patients at 17 epilepsy centers with MTL epilepsy who were treated with the RNS System using bilateral MTL leads, and in whom an MTL resection was subsequently performed. Presumed lateralization based on routine presurgical approaches was compared to lateralization determined by RNS System chronic ambulatory ICEEG recordings. The primary outcome was frequency of disabling seizures at last 3-month follow-up after MTL resection compared to seizure frequency 3 months before MTL resection. RESULTS: We identified 157 patients treated with the RNS System with bilateral MTL leads due to presumed bitemporal epilepsy. Twenty-five patients (16%) subsequently had an MTL resection informed by chronic ambulatory ICEEG (mean = 42 months ICEEG); follow-up was available for 24 patients. After MTL resection, the median reduction in disabling seizures at last follow-up was 100% (mean: 94%; range: 50%-100%). Nine patients (38%) had exclusively unilateral electrographic seizures recorded by chronic ambulatory ICEEG and all were seizure-free at last follow-up after MTL resection; eight of nine continued RNS System treatment. Fifteen patients (62%) had bilateral MTL electrographic seizures, had an MTL resection on the more active side, continued RNS System treatment, and achieved a median clinical seizure reduction of 100% (mean: 90%; range: 50%-100%) at last follow-up, with eight of fifteen seizure-free. For those with more than 1 year of follow-up (N = 21), 15 patients (71%) were seizure-free during the most recent year, including all eight patients with unilateral onsets and 7 of 13 patients (54%) with bilateral onsets. SIGNIFICANCE: Chronic ambulatory ICEEG data provide information about lateralization of MTL seizures and can identify additional patients who may benefit from MTL resection.


Asunto(s)
Lobectomía Temporal Anterior/métodos , Epilepsia Refractaria/cirugía , Epilepsia del Lóbulo Temporal/cirugía , Lóbulo Temporal/cirugía , Adulto , Anciano , Epilepsia Refractaria/fisiopatología , Terapia por Estimulación Eléctrica , Electrocorticografía , Epilepsia del Lóbulo Temporal/fisiopatología , Femenino , Humanos , Neuroestimuladores Implantables , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Procedimientos Neuroquirúrgicos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
3.
Epilepsia ; 59(6): 1198-1207, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29600809

RESUMEN

OBJECTIVE: To compare stereotactic radiosurgery (SRS) versus anterior temporal lobectomy (ATL) for patients with pharmacoresistant unilateral mesial temporal lobe epilepsy (MTLE). METHODS: This randomized, single-blinded, controlled trial recruited adults eligible for open surgery among 14 centers in the USA, UK, and India. Treatment was either SRS at 24 Gy to the 50% isodose targeting mesial structures, or standardized ATL. Outcomes were seizure remission (absence of disabling seizures between 25 and 36 months), verbal memory (VM), and quality of life (QOL) at 36-month follow-up. RESULTS: A total of 58 patients (31 in SRS, 27 in ATL) were treated. Sixteen (52%) SRS and 21 (78%) ATL patients achieved seizure remission (difference between ATL and SRS = 26%, upper 1-sided 95% confidence interval = 46%, P value at the 15% noninferiority margin = .82). Mean VM changes from baseline for 21 English-speaking, dominant-hemisphere patients did not differ between groups; consistent worsening occurred in 36% of SRS and 57% of ATL patients. QOL improved with seizure remission. Adverse events were anticipated cerebral edema and related symptoms for some SRS patients, and cerebritis, subdural hematoma, and others for ATL patients. SIGNIFICANCE: These data suggest that ATL has an advantage over SRS in terms of proportion of seizure remission, and both SRS and ATL appear to have effectiveness and reasonable safety as treatments for MTLE. SRS is an alternative to ATL for patients with contraindications for or with reluctance to undergo open surgery.


Asunto(s)
Lobectomía Temporal Anterior/métodos , Epilepsia del Lóbulo Temporal/radioterapia , Epilepsia del Lóbulo Temporal/cirugía , Radiocirugia/métodos , Adulto , Relación Dosis-Respuesta en la Radiación , Epilepsia Refractaria/radioterapia , Epilepsia Refractaria/cirugía , Epilepsia del Lóbulo Temporal/complicaciones , Epilepsia del Lóbulo Temporal/psicología , Femenino , Lateralidad Funcional , Humanos , Estudios Longitudinales , Masculino , Trastornos de la Memoria/diagnóstico , Trastornos de la Memoria/etiología , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Calidad de Vida , Método Simple Ciego , Resultado del Tratamiento , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/etiología
4.
World Neurosurg ; 84(3): 719-26, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25940211

RESUMEN

INTRODUCTION: The clinical results for the RNS System (NeuroPace, Mountain View, California, USA) closed-loop responsive neurostimulator for the treatment of medically intractable partial-onset seizures have been encouraging. The University of Southern California (USC) Neurorestoration Center and the Keck Hospital of USC have become the world's first institutions to implant an RNS System post U.S. Food and Drug Administration (FDA) approval. As one of the study centers, we review our experience with our group of patients who have been implanted with the RNS System. METHODS: A total of 40 surgeries by a single surgeon were performed on 10 patients (7 male and 3 female) with an average age of 39.2 years (24-66 years) and were followed for an average of 45 months (30-54 months). The average age at seizure onset was 14 years (birth-37 years) with an average of 4.7 (3-12) failed antiepileptic drugs. We reviewed the patients' charts for complications from the surgeries including infections requiring surgical intervention, hematomas, hardware failures, and death. RESULTS: Of the 40 surgeries, there were 10 initial implantations of the neurostimulator and leads, 24 neurostimulator replacements for expected end of neurostimulator service, 2 incision and drainage procedures (I & Ds) for soft tissue infection followed by 1 explantation and 1 reimplantation (same patient), and 2 revisions because of one lead that was damaged at the exit point between the skull and a titanium mesh and the second lead that was damaged at an acute bend over the skull (same patient). Eight of the patients had no complications and underwent an average of 2.7 neurostimulator replacements over 7 consecutive years to date. Each patient underwent routine postoperative computed tomography imaging of the brain, and none had any intracranial hematomas or misplaced leads requiring revision surgery. Finally, there were no deaths in our patient population. CONCLUSIONS: Our experience with the NeuroPace RNS System over an average follow-up of 45 months suggests that the surgery and device are safe when placed by an experienced surgeon. Although there were no clinically significant hematomas or patient deaths, we did have 1 patient each with infection and lead damage at the point of exit from the skull. We compare the results of this study with other neuromodulation procedures for epilepsy to evaluate the safety and complications associated with the RNS System. Our initial experience suggests that the RNS System can be readily incorporated into an active epilepsy surgical center.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Epilepsias Parciales/terapia , Adulto , Anciano , Resistencia a Medicamentos , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Electrodos Implantados , Falla de Equipo , Femenino , Estudios de Seguimiento , Lateralidad Funcional , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos , Estudios Retrospectivos , Técnicas Estereotáxicas , Infección de la Herida Quirúrgica/terapia , Resultado del Tratamiento , Adulto Joven
5.
Epilepsia ; 55(3): 432-41, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24621228

RESUMEN

OBJECTIVE: To demonstrate the safety and effectiveness of responsive stimulation at the seizure focus as an adjunctive therapy to reduce the frequency of seizures in adults with medically intractable partial onset seizures arising from one or two seizure foci. METHODS: Randomized multicenter double-blinded controlled trial of responsive focal cortical stimulation (RNS System). Subjects with medically intractable partial onset seizures from one or two foci were implanted, and 1 month postimplant were randomized 1:1 to active or sham stimulation. After the fifth postimplant month, all subjects received responsive stimulation in an open label period (OLP) to complete 2 years of postimplant follow-up. RESULTS: All 191 subjects were randomized. The percent change in seizures at the end of the blinded period was -37.9% in the active and -17.3% in the sham stimulation group (p = 0.012, Generalized Estimating Equations). The median percent reduction in seizures in the OLP was 44% at 1 year and 53% at 2 years, which represents a progressive and significant improvement with time (p < 0.0001). The serious adverse event rate was not different between subjects receiving active and sham stimulation. Adverse events were consistent with the known risks of an implanted medical device, seizures, and of other epilepsy treatments. There were no adverse effects on neuropsychological function or mood. SIGNIFICANCE: Responsive stimulation to the seizure focus reduced the frequency of partial-onset seizures acutely, showed improving seizure reduction over time, was well tolerated, and was acceptably safe. The RNS System provides an additional treatment option for patients with medically intractable partial-onset seizures.


Asunto(s)
Terapia por Estimulación Eléctrica/tendencias , Epilepsias Parciales/diagnóstico , Epilepsias Parciales/terapia , Neuroestimuladores Implantables/tendencias , Adolescente , Adulto , Anciano , Método Doble Ciego , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida/psicología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA